Sensor / Detector:

 

  • Sensor (probe) displays the output value as a continuous variable (° C, ° F, Ohms, V, mA,% RH, etc..). 
    Our sensors are connected to the bus 1-Wire(UNI) - RJ11 or RS-485 (RJ45).
  • Detectors show status as 0/1 (On/Off) and connect the DI inputs to Dry Contact inputs (terminal block).

Capable of Sensing:

 
 
Request a Quote


Sensors, Detectors and accessories

Sensors or probes and detectors you can connect to HW group products. 
Temperature, humidity, smoke, gas, pt-100 temperature probe, air-pressure, water detector, air-flow detector, water leak detector.


 

Temperature

      • HTemp-485, up to 1000m, accuracy ± 0.5 °C / ± 2% RHHTemp-485, up to 1000m, accuracy ± 0.5 °C / ± 2% RHTemp-1Wire 
        Temperature: indoor / outdoor / coolers, icebox and freezer / rack montage
        • Interface: 1-Wire (RJ11)
      • HTemp-1Wire 
        Temperature + Humidity: indoor / outdoor / rack montage
        • Interface: 1-Wire (RJ11)
      • Temp-485
        • Interface: RS-485 bus (Poseidon2 4002), up to 1 000m, RJ45 & terminal block 
        • Construction: Wall mount – indoor sensor
      • Temp-485-Pt100 Box2
        • Interface: RS-485 bus (Poseidon2 4002), up to 1 000m, terminal block 
        • Construction: IP67 wall mount – external sensor
      • Converters for the Pt100 temperature sensor
        • Converter 2xPt100 1W-UNI 
          • Interface: 1-Wire UNI (RJ11) - up to 60m
          • Temperature probe: Two channels for external Pt100 or Pt1000
          • Construction: Wall mount converter, temperature probe can be included (by order code)
             
        • Temp-485-Pt100 Cable3
          • Interface: RS-485 bus (Poseidon2 4002), up to 1000m, terminal block 
          • Construction: Wall mount converter, external temperature probe
        • Temp-485-Pt100 Frost2
            • Extended temperature range: -190 .. +150°C – outdoor sensor
            • Interface: RS-485 bus (Poseidon2 4002), up to 1000m, terminal block 
            • Construction: Wall mount converter, external temperature probe
     

Humidity

    • Humid-1Wire HTemp-485, up to 1000m, accuracy ± 0.5 °C / ± 2% RHHTemp-485, up to 1000m, accuracy ± 0.5 °C / ± 2% RHHTemp-485, up to 1000m, accuracy ± 0.5 °C / ± 2% RH
      Relative humidity sensors
      • Interface: 1-Wire (RJ11) 
         
    • HTemp-1Wire
      Temperature + Humidity: indoor / outdoor / rack montage
      • Interface: 1-Wire (RJ11) 

    • HTemp-485
      • Accuracy: ±0.5°C temperature / 5% RH humidity
      • Interface: RS-485 bus (Poseidon2 4002), up to 1000m, RJ45 & terminal block   
      • Construction: Wall mount – indoor sensor
    • HTemp-485 T3411 / T3419 / T7410
      • Accuracy: ±0.4°C temperature / ± 2.5% RH humidity
      • Interface: RS-485 bus (Poseidon2 4002), up to 1000m, 2 terminal blocks 
      • Construction: Wall mount – outdoor sensor
      • Note: Display with current values

DI (digital Inputs) expansion

  • Expander 4xDI 1W-UNI - Expansion module for connecting external Dry Contact inputs 
    • Input: 4x dry contact input – any detector (e.g. door contact)
    • Interface: 1-Wire UNI (2x RJ11 for daisy-chaining)
    • Connects to: Poseidon 2250, 4002, Ares 12/14, Poseidon2
    • Power: Bus-powered (1-Wire UNI) or external 5V adaptor

 

Air pressure

    •  PHTemp-485 T7410
      • Measurement: Air pressure, Temperature, RH humidity, Dew point
      • InterfaceRS-485 bus (Poseidon2 4002), up to 1000m, 2 terminal blocks 
      • Construction: Wall mount – outdoor sensor
      • Note: Display with current values

Light (luminous intensity)

Flood (water level & leak) detectors

      • HWg-WLD Relay 
        WLD (Water Leak Detection) sensing cable for surface 2D liquid detection. 
        Can be used as detector (relay output) or sensor powered from RJ11 and connected to 1-Wire UNI bus.
        • Interface 1: 1-Wire UNI (2x RJ11 for daisy-chaining)
        • Interface 2: Relay output (NO/NC) - connect to DI (Digital Input)
           
      •  Flood detector 1W-UNI 3m (sensor interface) 
        Water detection at a specific point (1D water detection). Simple wiring, no external power required. 
        Connects to Ares or Poseidon2 using the 1-Wire UNI (RJ11) interface. 
        • Interface: 1-Wire UNI (3m cable)
    •  Flood detector LD-12 
      One point water flood detector. Wall montage. 
      External power required.
      • Interface: Digital output - connect to DI (Digital Input)

 

Smoke and gas detectors

      • Smoke detector 
        Optical Smoke Detector to detect smoke and signal a fire alarm.
        • Interface: Relay output - connect to DI (Digital Input)
    • Detector of flammable gases 
      The detector GS-133 indicates flammable gas escape. The sensor detects all types of flammable gasses (natural gas, coalgas, propane, bottle-gas, acetylene, hydrogen, etc.).
      • Interface: Relay output - connect to DI (Digital Input)

Voltage and current sensors

      •  30A Current probe 1W-UNI
        The Current sensor up to 30A AC. Based on split-core single-phase current transducer. It's indirect measurement sensor - you don't have to cut the wire.
        • Interface: 1-Wire UNI (2x RJ11 for daisy-chaining)
      • Sensor 0- 60V 1W-UNI 
        Voltage sensor for 0 to 60V DC. 
        Electrically isolated, typically used to monitor battery voltage in telco applications (-48V standard).
        • Interface: 1-Wire UNI (2x RJ11 for daisy-chaining)
      • Sensor 0-20mA 1W-UNI 
        Current sensor for 0 to 20 mA DC current measurement. Can be used with the “source” type of the external probe. 
        It's typically used with current transformers and other industrial probes.
        • Interface: 1-Wire UNI (2x RJ11 for daisy-chaining)
      • Sensor 4-20mA 1W-UNI 
        Current sensor for 4 to 20 mA DC current measurement. Provide power for the current loop. Can be used with the “sink” type of the external probe. 
        It's typically used to connect output of the CO2 probe, tank level probe or other industrial probes. 
        • Interface: 1-Wire UNI (2x RJ11 for daisy-chaining) 

      • PowerEgg2 
        110V to 230VAC mains voltage detector and controller with electrical isolation.
        • Power detector Interface: Relay output (NO/NC) - connect to DI (Digital Input)
        • Power control Interface: Dry contact + Wet contact input (Switch on/off power by low voltage relay contact) 

Motion and position detectors

    • Shock (vibration) detector
      Detects vibrations, quivers, shocks and similar phenomena.
      • Interface: Digital output - connect to DI (Digital Input)

Bus accessories

  • RS-485 bus
    • Poseidon B-Cable to convert RS-485 line + power supply from RJ45 connector to terminal boardPoseidon B-Cable reduction [600 044] (photo
      It converts RS-485 line + power supply from RJ45 connector to terminal board - 4 pins (A,B,+,- )
    • Poseidon S-Hub to switch RS-485 line to 8+1 RJ45Poseidon S-Hub [600 041] (photo
      RS-485 line switch for 8+1 RJ45 connectors and TP cables. S-Hub can be used as a power supply for all connected sensors.
    • Poseidon Spider 
      Connects 4 dry contacts or 1-Wire bus RJ11 sensors to Poseidon2 4002 and RS-485 (RJ45) bus.
  • 1-Wire / 1-Wire UNI Bus
    • 1-Wire hub Power 
      1-Wire bus splitter for 8 ports with boosted power  
    • Poseidon T-Box 1250 to switch up to 5 sensors to 1-Wire busPoseidon T-Box
      A switch to connect up to 5 sensors to 1-Wire bus (5x RJ-12)  

Accessories